Already a customer? Login

 S-Dome 10° Flat Roof SystemK2 Mounting Systems

The solution for single-sided elevation. The S-Dome system is suitable for nearly all types of flat roofs. It is very easy to install using fewer K2 System components.

-   A system for structurally challenging roofs with limited ballast options
-   Aerodynamically optimised as a result of wind tunnel testing
-   Quick and easy handling 

TECHNICAL DATA

Side view S-Dome system
 
S-Dome
Scope of application: Flat roofs < 5° with film and bitumen covering or concrete; also trapezoidal sheet metal roofs with continuous mounting rails
Fastening type/roof fixture:  Stable, with ballasting if necessary; no roof penetration
Requirements:
-   Permissible module dimensions (L × W × H): 1550 - 1700 × 950 -1100 × 30 - 50 mm
-   Minimum system size: one row x 3 modules
-   Roof inclination of up to 5°
-   Technical specifications: 

Thermal separation after max. 13.5 m: min. 30 mm to max. 150 mm

Inclination angle: 

10°

Material:

 

-   Mounting rails, S-Dome, Dome SD, Windbreaker, module clamps, rail connectors: Aluminium EN AW-6063 T66
-   Building protection mat with or without aluminium lining (PUR-bound rubber granules)
-   Small parts: Stainless steel (1.4301) A2-70

S-Dome 10° Flat Roof System

 S-Dome 10° Flat Roof SystemK2 Mounting Systems

The solution for single-sided elevation. The S-Dome system is suitable for nearly all types of flat roofs. It is very easy to install using fewer K2 System components.

-   A system for structurally challenging roofs with limited ballast options
-   Aerodynamically optimised as a result of wind tunnel testing
-   Quick and easy handling 

TECHNICAL DATA

Side view S-Dome system
 
S-Dome
Scope of application: Flat roofs < 5° with film and bitumen covering or concrete; also trapezoidal sheet metal roofs with continuous mounting rails
Fastening type/roof fixture:  Stable, with ballasting if necessary; no roof penetration
Requirements:
-   Permissible module dimensions (L × W × H): 1550 - 1700 × 950 -1100 × 30 - 50 mm
-   Minimum system size: one row x 3 modules
-   Roof inclination of up to 5°
-   Technical specifications: 

Thermal separation after max. 13.5 m: min. 30 mm to max. 150 mm

Inclination angle: 

10°

Material:

 

-   Mounting rails, S-Dome, Dome SD, Windbreaker, module clamps, rail connectors: Aluminium EN AW-6063 T66
-   Building protection mat with or without aluminium lining (PUR-bound rubber granules)
-   Small parts: Stainless steel (1.4301) A2-70
Page:
  1. 1
  2. 2
  3. 3

1-12 of 29

Set Descending Direction

Grid List