Already a customer? Login

K2 Mounting Systems

D-DOME 10° FLAT ROOF SYSTEM

The solution for double-sided elevation. The D-Dome System is suitable for nearly all types of flat roofs. It is very easy to install using fewer K2 System components.

-   A system which provides optimal surface utilisation and yields for roofs with limited ballasting options
-   Aerodynamically optimised as a result of wind tunnel testing
-   Quick and easy handling
-   Also available as a short rail system

TECHNICAL DATA

Side view D-Dome system
 

D-Dome

Scope of application: 

Flat roofs < 5° with film or bitumen covering and concrete; also trapezoidal sheet metal roofs with continuous mounting rails

Fastening type/roof fixture: 

Stable, with ballasting if necessary; no roof penetration

Requirements:

 

-   Permissible module dimensions (L × W × H): 1550 -2000 × 950 -1100 × 30 - 50 mm
-   Minimum system size: one row x 3 modules
-   Roof inclination of up to 5°
Technical specifications:

 

-   Thermal separation after max. 13.5 m: min. 30 mm to max. 150 mm
-   Minimum clearance to roof edge 500 mm (350 mm to other obstructions)
Inclination angle: 

10°

Material:

 

-   Mounting rails, D-Dome, Dome SD, Module Clamps, Rail Connectors: Aluminium EN AW-6063 T66
-   Building protection mat with or without aluminium lining (PUR-bound rubber granules)
-   Small parts: Stainless steel (1.4301) A2-70

D-Dome 10° Flat Roof System

D-Dome 10° Flat Roof System

K2 Mounting Systems

D-DOME 10° FLAT ROOF SYSTEM

The solution for double-sided elevation. The D-Dome System is suitable for nearly all types of flat roofs. It is very easy to install using fewer K2 System components.

-   A system which provides optimal surface utilisation and yields for roofs with limited ballasting options
-   Aerodynamically optimised as a result of wind tunnel testing
-   Quick and easy handling
-   Also available as a short rail system

TECHNICAL DATA

Side view D-Dome system
 

D-Dome

Scope of application: 

Flat roofs < 5° with film or bitumen covering and concrete; also trapezoidal sheet metal roofs with continuous mounting rails

Fastening type/roof fixture: 

Stable, with ballasting if necessary; no roof penetration

Requirements:

 

-   Permissible module dimensions (L × W × H): 1550 -2000 × 950 -1100 × 30 - 50 mm
-   Minimum system size: one row x 3 modules
-   Roof inclination of up to 5°
Technical specifications:

 

-   Thermal separation after max. 13.5 m: min. 30 mm to max. 150 mm
-   Minimum clearance to roof edge 500 mm (350 mm to other obstructions)
Inclination angle: 

10°

Material:

 

-   Mounting rails, D-Dome, Dome SD, Module Clamps, Rail Connectors: Aluminium EN AW-6063 T66
-   Building protection mat with or without aluminium lining (PUR-bound rubber granules)
-   Small parts: Stainless steel (1.4301) A2-70